Part Number Hot Search : 
BQ100 90TFIR10 MAX998 ST25VF BC337 2SK0758 BD4211FV M063A
Product Description
Full Text Search
 

To Download DIB71CB235A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specifications are subject to change without notice (18.09.06) 1 monitoring relays product description ordering key housing function type item number output power supply range ? ac/dc over current monitoring relay ? current measured through internal shunt ? measuring range 0.5 to 5 a ac/dc ? adjustable current limit on relative scale ? adjustable hysteresis ? programmable latching at set level ? output: 8 a spdt relay normally de-energized ? for mounting on din-rail in accordance with din/en 50 022 (dia01) or plug-in module (pia01) ? 22.5 mm euronorm housing (dia01) or 36 mm plug-in module (pia01) ? led indication for relay and power supply on ? galvanically separated power supply type selection mounting output supply: 24 vdc supply: 48 vdc supply: 24/48 v ac supply: 115/230 v ac din-rail spdt dia 01 c 724 5a dia 01 c 748 5a dia 01 c b48 5a dia 01 c b23 5a plug-in spdt pia 01 c 724 5a pia 01 c 748 5a pia 01 c b48 5a pia 01 c b23 5a input (current level) dia01 terminals y1, y2 pia01 t er minals 5, 7 measuring ranges dir ect inter nal r esist. max. curr. ..5a: 0.5 to 5 a ac/dc 0.05 6 a max. current for 1 s 25 a standar d ct (examples) aac rms max. cur r . tadk2 50 a/5 a 5 to 50 a 60 a tad2 150 a/5 a 15 to 150 a 180 a tad6 400 a/5 a 40 to 400 a 480 a tad12 1000 a/5 a 100 to 1000 a 1200 a taco200 6000 a/5 a 600 to 6000 a 7200 a contact input dia01 terminals z1, y1 pia01 terminals 8, 9 disabled > 10 k enabled < 500 latch disable > 500 ms note: the input voltage cannot raise over 300 vac/dc with respect to ground (pia only) 1-phase ac/dc over current types dia01, pia01 input specifications output spdt r elay rated insulation voltage 250 v ac contact ratings (agsno 2 ) resistive loads ac 1 8 a @ 250 v ac dc 12 5 a @ 24 vdc small inductive loads ac 15 2.5 a @ 250 vac dc 13 2.5 a @ 24 vdc mechanical life 30 x 10 6 operations electrical life 10 5 operations (at 8 a, 250 v , cos ? = 1) operating frequency 7200 operations/h dielectric strength dielectric voltage 2 kvac (rms) rated impulse withstand volt. 4 kv (1.2/50 ?) output specifications dia 01 c b23 5a dia01 and pia01 are precise ac/dc over current monitor- ing relays. direct measuring or through current transformer. owing to the built-in latch function, the on-position of the r elay output can be maintained. the red led indicates the relay status. through the built-in shunt it is possible to monitor loads up to 5 a ac/dc. d ia01 p ia01
2 specifications are subject to change without notice (18.09.06) range setting centre knob: setting of current on relative scale: from 10 to 110% of the full-scale value. hysteresis: approx. 4% of set value, it can be extended by insertinga r esistor between ter minals z1, y1 or 8, 9. approx. resistor values: 10%: 180 k 25%: 47 k 50%: 22 k 75%: 15 k latch: < 500 dia01, pia01 mode of operation dia01 and pia01 monitor both ac and dc over current thr ough an inter nal shunt. they can monitor ac cur - rents up to 6000 a when connected to a suitable cur- rent transformer. example 1 (connection between termi- nals z1, y1 or 8, 9 - latch function enabled) the relay operates and latch- es in operating position when the measured value exceeds the set level. pr o- vided that the current has dropped min. 4% below the set point (see hyster esis) the r elay r eleases when the inter- connection between termi- nals z1, y1 or 8, 9 is inter-r upted or the power supply is inter r upted as well. example 2 (stardard ct) (no connection between ter- minals z1, y1 or 8, 9 - latch function disabled) the relay operates when the current flowing through the transformer exceeds the set level. it r eleases when the current drops min. 4% below the set level (see hysteresis) or when the power supply is inter r upted. power supply overvoltage cat. iii rated operational voltage (iec 60664, iec 60038) through terminals: a1, a2 or a3, a2 (dia01) 2, 10 or 11, 10 (pia01) 724: 24 vdc 20%, insulated 748: 48 vdc 20%, insulated b48: 24/48 vac 15% 4 5 to 65 hz, insulated b23: 115/230 vac 15% 45 to 65 hz, insulated dielectric voltage dc supply ac supply supply to input 2 kv 4 kv supply to output 4 kv 4 kv input to output 4 kv 4 kv rated operational power ac 4 va dc 2 w supply specifications reaction time (input signal variation from -20% to +20% or from +20% to -20% of set value) alarm on delay < 100 ms a larm off delay < 300 ms accuracy (15 min warm-up time) temperature drift 1000 ppm/ repeatability 0.5% on full-scale indication for power supply on led, green output relay on led, red environment (en 60529) degree of protection ip 20 pollution degree 3 (dia01), 2 (pia01) operating temperature -20 to 60, r.h. < 95% storage temperature -30 to 80, r.h. < 95% housing dimensions dia01 22.5 x 80 x 99.5 mm pia01 36 x 80 x 94 mm weight approx. 150 g screw terminals tightening torque max. 0.5 nm acc. to iec 60947 approvals ul, csa (except 748 models) ce marking ye s emc electromagnetic compatibillity immunity according to en 61000-6-2 emission according to en 61000-6-3 general specifications
specifications are subject to change without notice (18.09.06) 3 dia01, pia01 operation diagrams wiring diagrams dia01 pia01 power supply set level relay on hysteresis relay on hysteresis set level latch on power supply 24/48 vdc (+) 24/48 vdc (+) 24/48 vdc (+) 2 4/48 vdc (+) dimensions din-rail plug-in n (-) pe z1 y1 y 2 a1 a3 a 211 12 14 2 4 vdc (+) 48/230 vac 24/115 vac i l l atch/hysteresis adjustment example 1 example 2 n (-) 24 vdc (+) 4 8/230 vac 24/115 vac z 1 y1 y2 a 1a3 a2 11 1 214 i hysteresis adjustment l ~ ~ ~ ~ - + example 1 n (-) pe 8 9 5 7 1 1 2 10 1 4 3 24 vdc (+) 4 8/230 vac 2 4/115 vac i l l atch/hysteresis adjustment example 2 n (-) 24 vdc (+) 48/230 vac 2 4/115 vac 8 9 5 7 1 01 43 i hysteresis a djustment l 11 2 ~ ~ ~ ~ + - 22.5 8 0 8 3 . 5 99.5 6 3 28.5 36 8 0 94 28.5 6 3 90


▲Up To Search▲   

 
Price & Availability of DIB71CB235A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X